Nonconformance Report (NCR)
A nonconformance report (NCR) is the quality record raised when material, a part, or a process output fails to meet its drawing, specification, or acceptance criteria. It identifies the defect, quantifies how much is affected, segregates the suspect material, and carries the authorized disposition.
A nonconformance report (NCR) is the document that turns a discovered defect into a controlled event rather than a judgment call. It is raised at receiving inspection, in process, at final inspection, during test, or on a customer return, by whoever finds the deviation. A usable NCR states the part number and revision, the lot or serial numbers affected, the quantity inspected and the quantity rejected, the specific characteristic that failed with the actual reading against the requirement, the work order and operation where it surfaced, and how it was detected. An NCR that says bad weld is worthless a year later when a customer asks what happened to that lot.
The record drives three things in sequence: identification, segregation, and disposition. Tagging the material and moving it to a hold location is the step shops skip and regret, because unsegregated suspect stock gets picked and consumed. Containment then asks how far the defect reaches, which means the rest of the lot, the lot before it, work in process downstream, and anything already shipped. Disposition is rendered only by authorized personnel, and anything beyond a routine scrap or rework call goes to a material review board: scrap, rework to full specification, repair to a usable non-standard condition, return to vendor, or use-as-is under a documented concession. The NCR stays open until the quantities reconcile, so scrapped plus reworked plus accepted plus returned equals the quantity rejected.
An NCR is not a CAPA, and conflating the two is the most common mistake. The NCR handles this lot; corrective and preventive action handles the process that made it. An NCR is not a scrap ticket either, since scrap is only one of its possible outcomes. When the defect originates at a supplier, the same record becomes the basis for a supplier corrective action request and any chargeback.
The value compounds in the aggregate. Counts by part number, operation, defect code, and supplier are what reveal the lathe, the fixture, or the vendor that deserves an investigation, which is why a free-text defect field quietly destroys the data. Standards requiring control of nonconforming product expect identification, segregation, documented review, and disposition by authorized people, and the signed NCR is the evidence that happened. In a real shop the test of the system is whether an auditor can pick any hold tag on the floor and find the matching open record in under a minute.
A sheet-metal shop receives 500 stainless brackets and receiving inspection measures a 4.2 mm mounting hole on a sample of 20 against a 4.0 mm requirement with a 0.1 mm tolerance. The inspector raises NCR 2214, tags the pallet, and moves it to the hold cage. Expanded inspection of all 500 finds 180 oversize. The disposition returns 180 to the vendor against the purchase order and accepts 320. The record closes when 320 plus 180 reconciles, and the supplier scorecard takes a 36 percent lot rejection.
What is the difference between an NCR and a CAPA?
An NCR controls the specific nonconforming material in front of you: identify it, segregate it, disposition it. A CAPA addresses the process that produced it so the next lot is good. A single NCR usually closes with a correction. A pattern of NCRs on the same part, operation, or supplier is what should open a CAPA.
When do I have to raise a nonconformance report?
Whenever product or a process output fails a stated requirement: receiving inspection rejects, in-process and final inspection failures, test failures, customer returns, and deviations found during an audit. Raise it before the material moves, not after. If a requirement was not met and the material still has value to someone, there is an NCR to write.
What information does an NCR have to contain?
Part number and revision, lot or serial identification, quantity inspected and quantity rejected, the exact characteristic that failed with the actual reading against the requirement, where and how it was detected, the work order and operation, the segregation location, the disposition, and the signature and date of whoever authorized that disposition.
Who is allowed to disposition a nonconformance?
Only personnel the quality system authorizes by name or role. Routine scrap and rework calls often sit with a quality engineer. Use-as-is, repair, and anything touching a customer requirement go to a material review board, and a concession against a customer specification normally needs the customer's written agreement before it is valid.
How long should nonconformance records be kept?
For the retention period your quality system and your customer contracts define, which in aerospace and medical work is often tied to the service life of the product. Keep the disposition, the quantities, and the signatures attached to the lot identification, because the whole value of the record is answering later which units were affected.